Locate A Sales Representative
Home
|
About Us
|
Products
|
Repairs & Field Service
|
Contact
Regenerative Industrial Dryers
Heatless Dryers
Heated Dryers
BP Dryers
Mini Dryers
Accessories
Filters
Accessories and Options
Part Numbering System
Dew Point Demand Plus
Dew Point Demand
High Humidity Alarm
RS-232 Serial Communication Interface
Heater Overtemp Alarm
Remote Alarm Contacts
Remote Alarm Dry Contacts
-100°F Pressure Dew Point
Low Ambient Package
Power Saver Thermal
Blower Purge Cool Down Loop
Nema 7 Electrical Construction
Total Pneumatic Controls
Pre-Piped Connection with Pre and After filter
3-Valve Bypass w/Pre-piped Connection
7-Valve Bypass w/Pre-piped Connection
Heater Options (RE Dryers Only)
Remote Alarm Contacts
Pre-Piping and Bypass
RS232 Interface
Low Ambient
Cool Down Loop (BP Dryers Only)
Model Number
Dryer Size
Dew Point
Voltage
Electrical Construction
Dew Point Control & Monitoring Options
Model
:
Model
Description
RH
Heatless Regenerative Dryer
RE
Externally Heated Regenerative Dryer
BP
Blower Purge Regenerative Dryer
Dryer Size
:
RH
RE
BP
SCFM
203
X
X
35
204
231
X
50
205
232
X
75
206
233
X
100
207
X
X
125
208
234
X
150
209
235
123
200
210
236
X
250
211
237
X
300
212
238
144
350
213
239
X
400
214
240
X
500
X
X
185
600
215
241
X
650
216
242
X
750
X
X
205
800
217
243
X
900
218
244
245
1100
219
245
X
1300
220
246
305
1500
221
247
X
1800
222
248
325
2100
223
249
365
2500
224
250>
366
3000
X
X
425
4000
X
X
485
5000
X
X
545
6500
X
X
605
8000
X
X
665
10000
X
X
725
12000
Dewpoint
:
A
-40°F
B
-100°F
Voltage
:
1
120V/1ph/60Hz
2
480V/3ph/60Hz
3
220V/1ph/60Hz
4
220V/3ph/60Hz
5
None
6
380V/3ph/50Hz
Electrical Construction
:
A
Nema 4
B
Nema 7
C
Total Pneumatic Controls (RH Dryers only)
Dew Point Control & Monitoring Options
:
1
None
2
Dew Point Demand Plus
3
Dew Point Demand
4
Dew Point Demand and High Humidity Alarm
5
High Humidity Alarm
Heater Options (RE Dryers Only)
:
A
None
B
Heater Overtemp Alarm
C
Power Saver Thermal Control
D
Heater Overtemp Alarm and Power Saver
Remote Alarm Contacts Options
1
None
2
Remote Alarm Contacts (120V)
3
Remote Alarm Dry Contacts
Pre-Piping and Bypass Options
:
A
None
B
Pre-Piped Filter Package
C
Pre-Piped Filter Package with three valve dryer bypass
D
Pre-Piped Filter Package with seven valve dryer bypass
RS-232 Interface Option
1
None
2
RS-232 Serial Communications Interface
Low Ambient Option
:
A
None
B
Low Ambient Insulation
Cool Down Loop Option (BP Dryers Only)
1
None
2
Blower Purge Cool Down Loop
About Us
|
Products
|
Repairs & Field Service
|
Contact
Sitemap
|
Login
|
Distributor Login
|