Model # |
H.P. |
Air Flow CFM |
Voltage |
AMPS LRA |
LRA |
Max
Fuse |
Refrig Charge* R-134A |
Dimension
(In) |
Air
Line connection |
KW
Input |
Weight
Lbs. |
||
L |
H |
W |
|||||||||||
F-3528 |
.25 |
21 |
115/1/60 208-230/1/60 |
5.3 |
29 |
15 |
20oz |
22.25 |
16 |
14 |
1"
FPT |
.48 |
84 |
F-3529 |
.5 |
30 |
115/1/60 208-230/1/60 |
5.36 |
30 |
15 |
1.8 Lbs. |
30.25 |
27.5 |
20 |
1"
FPT |
.91 |
147 |
F-3530 |
1 |
50 |
115/1/60 208-230/1/60 |
16.9 |
78 |
20 |
2.8 Lbs. |
30.25 |
27.5 |
20 |
1"
FPT |
1.90 |
187 |
F-3531 |
1.25 |
70 |
230/1/60 208-230/3/60 460/3/60 |
12.4 |
61 |
15 |
3.8 Lbs. |
34.25 |
35 |
27 |
2"
MPT |
2.10 |
275 |
F-3532 |
1.5 |
105 |
230/1/60 208-230/3/60 460/3/60 |
16.0 |
82 |
20 |
4.5 Lbs. |
34.25 |
35 |
27 |
2"
MPT |
2.60 |
280 |
| Note: Above units are rated for 160°F saturated air inlet temperature due to the fact that there is physically no more moisture heat above this temperature. The units, however, are designed for 180°F inlet temperature and 100°F ambient temperature. Maximum operating pressure is 250 psig | |||||||||||||