Air Flow Ratings
Air dryer rated flows are based upon design conditions of 100°F inlet,
100 psig and 100°F ambient. If these conditions vary, the rated flows will
vary in accordance with the following general rules and tables.
Inlet AIr Temperature |
90°F |
95°F |
100°F |
110°F |
120°F |
Flow Capacity Multiplier |
1.23 |
1.13 |
1.00 |
0.83 |
0.69 |
Air Line Pressure |
60 psig |
80 psig |
100 psig |
120 psig |
150 psig |
Flow Capacity Multiplier |
.88 |
.95 |
1.00 |
1.04 |
1.08 |
Ambient Air Temperature |
80°F |
90°F |
100°F |
110°F |
Flow Capacity Multiplier |
1.14 |
1.07 |
1.00 |
.92 |
Dew Point |
39°F |
45°F |
50°F |
Flow Capacity Multiplier |
1.05 |
1.15 |
1.20 |
Moisture Removal Data
120 |
70 |
.05613 |
26.94 |
3.23 |
100 |
70 |
.02455 |
11.78 |
1.41 |
90 |
70 |
.01399 |
6.718 |
.81 |
80 |
70 |
.005965 |
.005965 |
.34 |
120 |
50 |
.06386 |
.06386 |
3.67 |
100 |
50 |
.03227 |
15.49 |
1.86 |
90 |
50 |
.02172 |
10.43 |
1.25 |
80 |
50 |
.01369 |
6.571 |
.79 |
120 |
35 |
.06714 |
32.23 |
3.86 |
100 |
35 |
.03556 |
17.07 |
2.05 |
90 |
35 |
.02501 |
12.00 |
1.44 |
80 |
35 |
.01698 |
8.149 |
.98 |
Standard Instrument Panels
On/Off Switch/Light |
|
X |
X |
X |
X |
X |
Power On Light |
X |
|
|
|
|
|
High Temp Light |
X |
|
|
|
|
|
Refrigerant Suction Gauge |
X |
X |
X |
X |
X |
X |
Air Inlet Temp Gauge |
|
|
|
X |
|
|
Discharge Pressure Gauge |
|
|
|
|
|
X |
Manual Drain Override |
|
|
|
|
X |
X |
Drain Alarm Light |
|
|
|
|
X |
X |
Voltage Codes
1 |
115/1/60 |
100/1/50 |
2 |
208-230/1/60 |
200-240/1/50 |
3 |
208-230/3/60 |
200-240/3/50 |
4 |
460/3/60 |
380/3/50 |
5 |
575/3/60 |
|
|